![]() ![]() Never place the basin directly in contact with rocks or other sharp objects. Excavation: Excavate the hole as small as possible, with a minimum recommended 8" diametrical clearance around the tank. In Ground Installation of Pro-Series BasinsĪ. To remove the clear cover, simply pull upward disengaging it from the threaded ports. The cover is snapped into the threaded ports of the cover. The protective cover should remain in place until finish plumbing however, can be removed and reinstalled if required. Provore ® P380 and P680 systems feature a clear disposable construction cover designed to protect the system during rough-in and masonry work. QuickTree ® floats are preset at the factory for optimum operating levels and should not be adjusted. There is no need to disconnect plumbing or remove the pump to inspect service or replace floats. Floats for both pump activation and alarm (if equipped) are mounted on a stainless steel tree (rod), separate from the pump. The QuickTree ® system is located under a separate access cover for ease of maintenance and service. ![]() QuickTree ® Technology: ProVore ® P380 and P680 systems by Liberty Pumps features QuickTree ® float technology. Consult Factory for proper pump sizing prior to installation. Was your system sized by a professional? Minimum fluid flows are required in sewage applications. Pump and Alarm floats are pre-set on the QuickTree ® system at proper operating levels. Note: All P380-Simplex and P680-Duplex Systems are shipped standard with 16 cover bolts and pass the 10’ Stack Test. Also systems are available with an 8” extension to increase the height of the basin these models are designated with an X8 example: P382X8XPRG101. “/A2” …ALM-2, “/A2W” …ALM-2W all Pro 680 systems come with an integral control system with alarm. Pro 380 Systems ordered with alarm option have an “/A” suffix designating the alarm. Your specific pump is identified by the model number on the nameplate attached to the Pro-Series cover. The following chart lists the grinder pumps available. System: The ProVore ® residential grinder system is shipped from the factory fully assembled. The Uniform Plumbing Code (UPC) states that sewage systems shall have an audio and visual alarm that signals a malfunction of the system, to reduce the potential for property damage. The installation must be in accordance with the National Electric Code and all applicable local codes and ordinances.ĭo not use these pumps in water over 140 F. These pumps are not to be installed in locations classified as hazardous in accordance with the National Electric Code, ANSI/NFPA 70. The electrical outlet or panel shall be within the length limitations of the pump power cord, and at least 4 feet above floor level to minimize possible hazards from flood conditions. Make sure the power source is properly sized for the voltage and amperage requirements of the motor, as noted on the pump nameplate. This pump requires separate, properly fused and grounded branch circuit. To reduce the risk of electric shock, be certain that the grounding conductor is connected only to a properly grounded control panel or, if equipped with a grounding-type plug, that it is connected to a properly grounded, grounding-type receptacle.ĭo not bypass grounding wires or remove ground prong from attachment plugs.ĭo not remove cord and strain relief, and do not connect conduit to pump. This pump is supplied with a grounding conductor or a grounding-type attachment plug. The electrical connections and wiring for a pump installation should only be made by qualified personnel. To reduce risk of electric shock, always disconnect pump from power source before handling. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service. Each Liberty pump is individually factory tested to insure proper performance. Please consult factory for proper pipe and system sizing.īefore installation, read the following instructions carefully. Discharge sizes may be reduced to 1-1/2” or 1-1/4”. Do not increase this pipe size above 2” as adequate flow rates may not be achieved for proper operation. The ProVore ® system is supplied with a 2” discharge outlet. Its unique cutter system grinds difficult wastes and then pumps it through a 1-1/2” or 2” discharge line. residential grinder system easily handles solids and sewage waste found in typical residential applications. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |